The MPC-365 System consists of the MPC-200 controller and one to six MP-865 micromanipulators.

Product Enquiry

If you would like to send us an enquiry about this product, please click the button below, fill in the form and submit.

Product Enquiry

Product Enquiry

Please fill out the form if you would like to enquire about this product.

"*" indicates required fields

Name
Please indicate the name of your University or company
We would really like to stay in touch, so that we can inform you about new products, training events and other news that we think might be of interest to you. To comply with data protection regulations, we can only contact you in this way if we have your explicit permission to do so. By ticking the opt in box you are giving consent for Linton Instrumentation to process your data and you understand that you have the right to withdraw it at any time.*

Narrow-Format MP-865 Based Multi-Micromanipulator Systems

The MPC-365 System consists of the MPC-200 controller and one to six MP-865 micromanipulators.

MPC-200 Controller and ROE

Neurobiological experiments are becoming more complex. Many require multiple manipulators with control units that quickly become space and/or cost prohibitive. The MPC-200 is the solution you have been asking for. A single controller capable of running two manipulators! Sutter Instrument has taken the simplicity of the MP-225 controller and expanded it to run two manipulators from a single controller/ROE. The MPC-200 works with one or two of our world-renowned mechanicals, the MP-285 (MPC-385), the MP-225 (MPC-325) or the narrow format MP-865 (MPC-365).

If two manipulators aren’t enough, a second controller can be daisy chained to allow the single ROE-200 to move up to four manipulators. Thus the system can be easily expanded to control highly sophisticated experiments.

The Sutter MPC-200 is electrically quiet. Unlike the competition, our multi-unit controller employs linear output circuitry. Sutter adds additional manipulators to the same controller without requiring potentially noisy chopper drives.

In all our manipulators, the 4th axis can be set up and changed without the need to connect an external computer to download and configure software. A separate configuration is allowed for each output on this manipulator controller. If desired, each manipulator can approach the prep at a different angle from the horizontal. The 4th axis can be configured between the X and Z-axes or the Y and Z-axes (useful when manipulator is rotated 90 degrees relative to the preparation).

Faster automated pipette exchange. The MPC-200 has faster “Home” and “Work Position” moves for quicker pipette exchange. Automation is set up and run via the same interface used in the MP-225 controller; however, the speeds of the automated movement are much faster.

Accelerated manual mode. For users who prefer manual pipette exchange we have added “Accelerated Mode” to the ROE. Using Accelerated Mode, the user can make quick manual moves in and out of a setup. Accelerated Mode amplifies the speed attainable in a manual move by smoothly accelerating to the maximum speed during sustained, fast turns of the ROE. Accelerated movement ends as soon as the user stops turning the knob. This mode can be fully disabled for those who feel the need for direct control of the pipette.

MP-865 Micromanipulator

Our new MP-865 “narrow format” mechanical is designed specifically for patch-slice work that require more than 2 or 3 pipettes, as well as for other setups where space is limited. We designed the MP-865 to minimize the width, allowing as many manipulators to be grouped together as possible. Travel in the Y-axis is shortened (12.5 mm) because radially oriented manipulators do not require long travel in the traverse axis. Travel in the X-axis has been increased to 50 mm to facilitate fast and easy pipette exchange.

The optional narrow-format stand and linear slide or rotating base is available for mounting the MP-865 mechanical. With the 150 mm throw of the linear slide, the manipulator can be quickly and smoothly retracted out to a location where there is easy access to the pipette for replacement. A rotating base can be used for mounting to large platform stages like the Sutter MT-78, or smaller Sutter MD Series platforms.

Additional components can be added at any time, allowing the user to develop a system tailored to his or her particular needs. The controller is self-detecting so there is no need for manual configuration of the components.

Features

  • Quietest electronics in the industry optimized for single channel recording
  • Single controller and ROE will run two stepper motor drive manipulators
  • Self-detecting, daisy-chain capability allows control of four manipulators from one ROE-200
  • User-friendly interface: single button access to all major functions
  • Easily configurable virtual 4th axis set without external computer
  • Accelerated Mode for fast, manual manipulator movement
  • Easy toggle selection of Mode (speed/resolution, pulsed diagonal, Accelerated Mode)
  • Display indicates X, Y, Z coordinates, Mode, active manipulator
  • Robotic Home and Work Position moves for easy automated pipette exchange
  • Faster robotic moves than previous versions
  • Definable 4th axis for coaxial pipette movement, angle selected by DIP switches
  • Simple USB interface
  • Toggle switch selects which manipulator is connected to input device
  • LED and display indicate active manipulator
  • Ultra-low drift, ultra-smooth movement
  • Low-drift mechanical stability

Features: MP-865 Mechanical

  • Mechanically robust construction for high stability
  • Precision cross-roller bearings
  • Three independent axes – 50 mm travel in X, 12.5 mm in Y and 25 mm in Z
  • Carries up to a kilogram
  • Suited for in vitro and in vivo electrophysiological recording
  • Universal mounting system for headstage or pipette holder
  • Optional MT-73 narrow stand with linear slide and built in rotating base

 

Ordering Information

MPC-365 Systems

Catalog Number Description
MPC-365* One MP-865 manipulator mechanical, one MPC-200 controller, one ROE-200, mounting adapter plate, rod holder, hinged headstage mount, 4″ dovetail extension, manipulator and ROE connecting cables, power cord and manual
MPC-365-2* ROE-200 with MPC-200 and (2) MP-865 mechanicals
MPC-365-3* ROE-200 with (2) MPC-200 controllers and (3) MP-865 mechanicals
MPC-365-4* ROE-200 with (2) MPC-200 controllers and (4) MP-865 mechanicals
MPC-365-5* (2) ROE-200 with (3) MPC-200 controllers and (5) MP-865 mechanicals
MPC-365-6* (2) ROE-200 with (2) MPC-200 controllers and (6) MP-865 mechanicals

 

Components

MPC-200 Controller box alone. Purchase this if you intend to daisy-chain two controllers to one ROE-200. In this configuration, up to four manipulators can be controlled by a single ROE-200. NOTE: This is not a stand-alone device. In order to function, the MPC-200 must be connected to a second MPC-200 with ROE-200 attached or be connected to its own ROE-200. Includes daisy chain cable, power cord and manual
ROE-200 This is the ROE alone. Provides user input to one or more MPC-200 controllers. This component is intended for users who have an existing four-manipulator MPC-200 system with a single ROE-200 and wish to split it into two independent two-manipulator systems. Includes cable to connect ROE to controller
MP-865/M* The MP-865 manipulator mechanical alone. Includes mounting adapter plate, rod holder, 4 inch dovetail extension, and cable to connect manipulator to controller.
* Indicate right- or left-handed set-up when ordering

 

ACCESSORIES

MT-731 Narrow-format stand with linear slide
265RBI2 Rotating base for MP-865
MP-RISER-0.53 1/2 inch riser
MP-RISER-1.03 1 inch riser

1 Suitable for upright microscopes.
1 Useful with Sutter MD stand and large platform stages such as the MT-78-FS, MP-78 and MPC-78.
3 Risers can be combined to achieve desired height.

Technical Information and Manuals

User Manual
MPC-365 Operation Manual
MPC-365 External Control Quick Reference

Technical Information
MP-865: Mechanical Drawing

Product Information
MPC-165/365 Sales Flyer
Multi-Link Sales Flyer

 

Resolution and Full Travel
Minimal microstep size is 46.88 nanometers per microstep
Display has single micron resolution
Full travel is 50 mm in X, 25 mm in Z and 12.5 mm in Y

Maximum Speed
MP-265 mechanical
3 mm/sec

Long Term Stability
Drive Mechanism
< 0.5 micron / 24 hr

Dimensions
MPC-200 Controller
15.75 in x 10.75 in x 3.5 in | 40 cm x 27.3 cm x 9 cm
ROE-200
10 in x 6 in x 4 in | 25 cm x 15 cm x 23 cm

Weight
MP-865 (aluminum)
3.5 lbs | 1.6 kg

MPC-200 Controller
6.5 lbs | 3 kg
ROE-200
3.5 lbs | 1.6 kg

Electrical
115/230 Volts
50/60 Hertz power line

RoHS Compliant

MPC-200 CE Certificate
MPC-365 CE Certificate

 

You may also like…